Home > Soarnol Data > Other Barrier Property > Ammonia Water Barrier Property of "Soarnol®"

Soarnol Data

Ammonia Water Barrier Property of "Soarnol®"

Ammonia water barrier property of "Soarnol®" is shown in the following.

(1)Test Method

Procedure:

  1. nfuse a pouch with 100ml of 25% Ammonia water or distilled water(as reference)
  2. Measure weight decreace with time at the condition of 20deg C,65%RH

Sample : 

Pouch made of monolayer or multilayer film consisting of Soarnol (Surface area:433cm2)

Film Thickness(µm)
Monolayer film(Soarnol 32mol%) 30
Monolayer film(Soarnol 44mol%) 30
PP / Soarnol32mol% / PP 30 / 40 / 30

Result

Sample Permeability(g 100µm/m2 day)
Ammonia water distilled water(ref.)
Soarnol 32mol%-Monolayer Pouch 20 25
Soarnol 44mol%-Monolayer Pouch 3.0 2.4
Soarnol 32mol%-Multilayer Pouch 2.4 0.4

Data Prepared : 1 Sep. 2003

Page Top