Home > Soarnol Data > Basic Physical Property > Relationship between Relative Humidity and Tg

Soarnol Data

Relationship between Relative Humidity and Tg

Glass transition temperature(Tg) for each relative humidity with "Soarnol®" is shown in the following.

(1)Evaluation Method

Sample  :  Soarnol(32mol%,38mol%,44mol%)
Apparatus  :  Perkin Elmer DSC7
Programming rate  :  10°C / min

(2)Result

Sample Tg (deg C)
0% 45% 65% 72% 88% 100%
Soarnol 32mol% 60 38 37 16 - 3
Soarnol 38mol% 58 40 37 38 18 6
Soarnol 44mol% 55 38 36 37 - 8

Data Prepared : 1 Sep. 2003

Page Top